• 10/15/20kVA Large LCD High Frequency Online UPS

10/15/20kVA Large LCD High Frequency Online UPS

Phase: Three Phase
Type: On-line
Protection: Overcurrent
Rated Voltage: 220VAC/380VAC 3phase with Ground
Rated Frequency: 40-70Hz(50/60 Auto-Sense)
Voltage Regulation: 208/220/230/240VAC(±1%)
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
HP9316C Plus 10-20KVA
Frequency Regulation
50/60Hz±0.05%
Power Factor
0.9
Overload Capability
Linear Load<2%,Non-Linear Load<5%
Current Crest Ratio
3:1
Humidity
0~95% (Non-Condensing)
Operation Temperature
0~40ºC
Transport Package
Cartons and Pallets
Trademark
SOROTEC
Origin
China
Production Capacity
4500pcs/Month

Product Description

10/15/20KVA Large LCD High Frequency Online UPS


Key Features:
1. Large blue back light LCD for detailed Real-time UPS status display.
2. Advanced online pure sine wave power supply system, with bypass repair switch, It can provide a reliable, high quality AC power source to the precision equipments, can be used widely in different fields.
3. Widely used to computer equipments, telecommunication systems and Industrial automatic control equipments.
4. Truly online design, different from offline, it can adjust the input voltage, filtering, when the AC break off, the UPS will provide an uninterruptible power source from the backup batteries.
5. UPS will change to bypass mode when overloading or inverter fault, when overloading remove, UPS will turn to inverter mode automatically.
6. N+N Parallel Redundancy and Capacity expansion for 6-20K(up to three units)


Applications:
Servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom.
Technical Specifications of Telecom UPS HP9116C 6-10K (1pH in/1pH out)


Product Description:
Model HP9316C Plus 10-20KVA
10KT-XL 15KT-XL 20KT-XL
Rated Power 10KVA/9KW 15KVA/13.5KW 20KVA/18KW
Rated Voltage 220VAC/380VAC 3phase with ground
Rated Frequency 40-70Hz(50/60Auto-sense)
Input
Voltage Range Single phase:120-275VAC(176-275VAC full load)
Three phase: 209-475VAC(304-475VAC full load)
Power Factor >0.95(Three phase) ≥0.99
Output
Voltage Regulation 208/220/230/240VAC(±1%)
Frequency Regulation 50/60HZ±0.05 Hz
Power Factor 0.9
Voltage Distortion Linear load<2% Non-Linear load<5%
Overload Capability 105% ~ 125% for 10min; 125%~150% for 30s,> 150% for 500ms
Current Crest Ratio 3:1
Transfer Time 0ms (AC Mode ~Battry mode)
Battery
DC Voltage 192VDC 192/216/240VDC
Recharge Current 4A 4A(8A optional)
Display
LCD Display input/output Voltage, Frequency, Battery voltag, Battery capacity, Loading rate.
Communication
Interface Smart RS232,SNMP card (optional) USB (optional)
Environment
Operation Temperature 0~40ºC
Humidity 0~95% (Non-condensing)
Storage Temperature -25ºC - 55ºC
Sea Level Elevation <1500m
Noise Level(1m) <55dB
Physics Characteristic
Weight(KG) 16.9 3151.2
Dimensions :( Wx D x H )mm 212X420X500 248X565X500
 

Packaging & Shipping

10/15/20kVA Large LCD High Frequency Online UPS

Company Profile


Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards. 
10/15/20kVA Large LCD High Frequency Online UPS
10/15/20kVA Large LCD High Frequency Online UPS10/15/20kVA Large LCD High Frequency Online UPS

Certifications

1,QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC. 

2,Best Partner

We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world. 

10/15/20kVA Large LCD High Frequency Online UPS

FAQ

1.How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.

2.How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load. 
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.

3.How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.

4.How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now