Customization: | Available |
---|---|
Type: | Communications Equipment |
Support Network: | 5g |
Still deciding? Get samples of US$ 3500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
DC Connection Port 5G Power Integral 2K 220VAC Telecom Huawei Heat Resistant To Cold Station
DC unit, AC / DC input converted to-48Vdc output, support 3 line DC output, 1 line battery input.
AC unit which supports 3 line of constant AC output and 1 line.
DC connection Port. It can be connected to the battery and DC load output.
Battery unit provides reliable power preparation to AC and DC application.
DC distribution box is used to DC output path expansion.
Key Features:
Rapid deployment
1.Compact in size and light in weight;
2.Save station, save space;
3.Easy to handle and transport.
4.Flexible design with 10 minutes quick station of single person
5.Power unit and battery unit support modular capacity expansion.
6.Support pole installation and wall installation, and support flag installation.
7.Support multi - system input: AC, DC input
Brief introduction
HW distributed power supply is a new generation specially that designed for the terminal device of communication network.
It is mainly used for Easy Macro, indoor or out door of RRU room, AC and DC power supply,and other standby electric application.
It supports varies of installation methods, such as pole installation and wall installation, and support flag installationand surface mounted installation.It also has the advantages of easy to installation, expanding maintenance-free,and flexible power module.
Product model | AC/DC rectifier module HWD series | DC/DC boost module | Battery module | |||
System indicators | Type | Integral type (built in 20AH battery) |
Split mounting type | |||
Size | 300mm (W) ×200 mm (H)× 431mm (D) | 300mm (W) ×99 mm (H)× 431mm (D) | ||||
Weight | 27kg | 13kg | 11kg | 25kg | ||
Installation | wall-mounted,pole mounted,flag installation,angle steel tower installation | |||||
Rated power/Capacity | 1000W | 2000W | 3000W | 1000W | 2000W/20AH | |
Entry cable | Bottom in line, bottom out line | |||||
Protection class | IP65 | |||||
Work temperature | -40ºC~+55ºC | -40ºC~+55ºC 45ºC above applications need to be equipped with sunshade | ||||
The cooling mode | Natural heat dissipation | |||||
Environmental indicators | Storage/Transport Temperature |
-40ºC~+70ºC | ||||
Operating humidity | 5%~95%(non-condensing) | |||||
Altitude | -60m~4000m(For every 200m increase in altitude from 2000m to 4000m, the highest working temperature decreases by 1ºC) |
|||||
Input | Input format | 220VAC single phase/110VAC double live wire /HVDC | -48VDC | -48VDC | ||
Input voltage | AC:85~300VAC,HVDC:85~400VDC | -40VDC ~ -60VDC | -48VDC | |||
Input frequency | 45Hz~65Hz | NA | NA | |||
AC input | 1×220V/10A | 1×220V/20A | 1×220V/30A | NA | NA | |
AC lightning protection | Difference Mode:20kA, common mode:20kA | |||||
Output | Output power | 1000W | 2000W | 3000W | 1000W | |
Output voltage | 48VDC | 280VDC | -48VDC | |||
DC output | 3×10A(With a replaceable fuse) | 3×20A(With a replaceable fuse) | 3×30A(With a replaceable fuse) | 2×10A | 1×20A | |
DC lightning protection | Difference Mode:10kA, common mode:20kA | |||||
The module efficiency | ≥96% | ≥90% | NA | |||
Communication interface | Interface definition | 2× DB15 Port(CAN+3×DO+RS485+RS232) | 1 way CAN | 1 way CAN,1 way RS485 |
AC scenario power supply scheme
Product model | AC inverter module HWA series | Battery module | ||
System indicators | Type | Assembled type | ||
Size | 300mm (W) ×99 mm (H)× 431mm (D) | |||
Weight | 30kg | |||
Installation | wall-mounted,pole mounted,flag installation,angle steel tower installation | |||
Rated power/capacity | 1000VA | 2000VA | 2000W/20AH | |
Entry cable | Bottom in line, bottom out line | |||
Protection rank | IP65 | |||
Working temperature | -40ºC~+55ºC | -40ºC~+55ºC 45ºC above applications need to be equipped with sunshade | ||
Cooling mode | Natural heat dissipation | |||
Environmental indicators | Storage/transportation temperature | -40ºC~+70ºC | ||
Operating humidity | 5%~95%(No condensation) | |||
Altitude | -60m~4000m(2000m~4000m For every 200m increase in altitude, the highest working temperature B28 H10decreases by 1ºC) | |||
Input | Input formats | 220VAC one phase | -48VDC | |
Input voltage | AC:85~300VAC | -48VDC | ||
Input frequency | 45Hz~65Hz | NA | ||
Ac input | 1×220V/10A | 1×220V/20A | NA | |
Ac lightning protection | Dierence mode: 20kA, common mode: 20kA |
NA | ||
Output | Output power factor | 0.8(0.9 optional) | NA | |
Output power | 800W | 1600W | ||
Output voltage | 220VAC | -48VDC | ||
Ac output | 3×16A(With a replaceable fuse) | NA | ||
Module efficiency | ≥93% | NA | ||
Communication interface |
Interface definition | 2× DB15 Port(3×DO+RS232) | 1way *CAN,1way*RS485 |
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.
1,QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2,Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.
1.How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.
2.How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load.
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.
3.How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.
4.How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)