Basic Info.

Model NO.
HP9116C PLUS
Protection
Unbalanced Loads
Application
Industry
Classification
Lighting/Power
Standby Time
Long-acting Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Centralized Model
Brand
Sorotec
Model
High Frequency Online UPS
Output Power Factor
0.9
Frequency
50/60Hz
Parallel Working
3 PCS UPS
Transfer Time
0ms (AC Mode to Battery Mode)
Input Voltage Range
Single Phase: 120 ~ 275VAC ( 176-275VAC Full Load
Nominal Voltage
208/220/230/240VAC
Battery Voltage
192/216/240VDC
Voltage Distortion
Linear Load<2% ,Non-Linear Load<5%
LCD Display
Input/Output Voltage, Frequency, Battery Voltag, B
Transport Package
Standard Exported Cartons
Specification
CE; RoHS
Trademark
SOROTEC
Origin
China
Production Capacity
5000PCS/Month

Product Description

40~70HZ pure sine wave ups Advanced Parallel Technology and Input Topology Design

HP9116C /HP9316C 1-20KVA (1Ph in/1 Ph out& 3Ph in/1 Ph out) PLUS  Series High Frequency Online UPS

Model HP9116C/HP9316C PLUS 1-20KVA
Type High Frequency Online UPS
Phase 1Ph in / 1Ph out & 3Ph in /1 Ph out
Capacity 10-20kva
Output Power Factor 0.9
Nominal Voltage 220/230/240/380vac
Nominal Frequency 40-70HZ
Parallel Working Maximum 3PCS UPS
Battery Voltage 24/36/48/72/96V(1-3KVA);180/192V(6-10KVA);192/216/240V (10-20KVA)
Transfer Time 0ms


Muilti-function and Friendly Design
Advanced Parallel Technology

Stable parallel control technology make sure current sharing to 1%.

Select trip technology can avoid and isolation system fault then improved system availability.

Flexible extension capacity and redundance management that can satisfy all kinds of requirements.

Support maximum 3 units for parallel working Flexible strategy.
Flexible Strategy
On line mode provides higher system availability.

High efficiency mode provides more economic operation.

Frequency conversion provides more stable output.
 

More Flexible and  Powerful  Extendable Capacity
Battery Type Can Be Choice

1.Battery voltage can be choice depend on capacity , can satisfy different requirement.

2.Convenience to get more back up time and lower system invests.

3.Convenience to save cost of battery.

4.Intelligent battery monitors Charge current can be adjust.
Charge Current Can Be Adjust
Standant charge current 4A.

Support more discharge time and more capacity battery for 8A charger Input topology design.
Input Technology Design
1.Support three phase input or single phase input for three phase UPS

2.Super wide input voltage and frequency range suitable for bad power electirc environment

3.Digital control DSP technology and best power component make the system safe and reliable

40~70Hz Pure Sine Wave UPS Advanced Parallel Technology and Input Topology Design

Higher Power Factor /Higher Efficiency /Support Three Phase Input
Output Power Factor Up To 0.9

Output power factor is 0.9 that mean can take more load, if you take same load that can get higher reliability.
Input power factors up to 0.99

Three phase input model support three phase PFC , input THDI<5%

Output voltage regulation 1%, frequency regulation 0.1%, parallel current sharing 1%.

The efficiency up to 94%

Efficiency up to 93.5%when take the 30%load

ECO mode efficiency up to 98%

Application:
Data Center ,Bank Station,Network,Communication Equipment,Office,Automatic Equipment,
Monitor Equipment,Control System,Computer Center,Precision Equipment and so on



Technical Parameter:

Model HP9116C/HP9316C 10-20KVA PLUS
10KT-XL 15KT-XL 20KT-XL
Rated Power 10KVA/9KW 15KVA/13.5KW 20KVA/18KW
Rated Voltage 220VAC/380VAC 3phase with ground
Rated Frequency 40-70 Hz (50/60 Auto-sense)
Input
Voltage Range Single phase: 120 ~ 275VAC ( 176-275VAC full load ) Three phase: 209-475VAC ( 304-475VAC full load)
Power Factor >0.95(Three phase) ≥0.99
Output
Voltage Regulation 208/220/230/240VAC (±1%)
Frequency Regulation 50/60HZ±0.05 Hz
Power Factor 0.9
Voltage Distortion Linear load<2% ,Non-Linear load<5%
Overload Capability 105% ~ 125% for 10min; 125% ~ 150% for 30s,>150% for 500 ms
Current Crest Ratio 3:01
Transfer Time 0ms (AC mode→Battery mode)
Battery
DC Voltage 192VDC 192/216V/240VDC
Recharge Current 4A 4A (8A optional)
Display
LCD Display input/output Voltage, Frequency, Battery voltag, Battery capacity, Loading rate.
Communication
Interface Smart RS232,SNMP card (optional) USB (optional)
Environment
Operation Temperature 0~40ºC
Humidity 0~95% (Non-condensing)
Storage Temperature -25ºC~55ºC
Sea Level Elevation <1500m
Noise Level (1m) <55dB
Physics Characteristic
Weight(KG) 16.9 31
Dimensions :(Wx D x H)mm 212X420X500 248X565X500

  40~70Hz Pure Sine Wave UPS Advanced Parallel Technology and Input Topology Design
40~70Hz Pure Sine Wave UPS Advanced Parallel Technology and Input Topology Design40~70Hz Pure Sine Wave UPS Advanced Parallel Technology and Input Topology Design

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier