Customization: | Available |
---|---|
Type: | On-line |
Protection: | Unbalanced Loads |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Outside Power system UPS HW9110E 1-10KVA
IP55, with isolation inverter, inner battery room can put 2nos 12V 100AH battery.
Strong environment adaptability and wide input range
High-reliability, energy-saving and eco-friendly
Inverter isolation and pure sine wave communication networking system traffic monitor lighting
Online UPS protection function
Line interactive UPS
With pure sine wave output and battery room inside
Intelligent no-load shut-off (optional)
Automatic adaptive frequency
Features:
lHigh transfer efficiency, highest can reach 90%. No load cost is no more than 5W.
lOutput pure sine wave.
lProtections: against short-circuit, overload, battery reverse polarity, low-voltage, and over-voltage protection, etc.
lStrong ability of resist concussion, can load all kinds of electric apparatus and industry equipments, such as air condition, refrigerator, television, fan, washer, etc.
l with temperature control function, which can save energy consumption.
lwith overload automatic recovery function
lThe service life can reach a decade
Applications;
Servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom
Technical Specifications of Outdoor UPS HW9110E Series
Model | HW9110E 1-10KVA | ||||||||||
1KVA | 2KVA | 3KVA | 6KVA | 10KVA | |||||||
Capacity | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/.1KW | 6KVA/4.2KW | 10KVA/7KW | ||||||
Nominal Voltage | 220/230/240VAC | ||||||||||
Nominal Frequency | 50HZ/60HZ | ||||||||||
Input | |||||||||||
Voltage Range | 115~295VAC(±3VAC) | 176~297VAC(±3VAC) | |||||||||
Frequency Range | 50HZ:(46HZ~54HZ); 60HZ:(56HZ~6HZ) | ||||||||||
Soft Start | 0~100% 5sec | ||||||||||
Power Factor | 0.98 | ||||||||||
Output | |||||||||||
Voltage Precision | 223/230/240x(1±2%) | ||||||||||
Frequency Precision | 50/60HZ±0.05HZ | ||||||||||
Power Factor | 0.7/0.8(Optional) Standard 0.7 | ||||||||||
Wave Distortion | Linear load<3% Non-linear<6% | ||||||||||
Overload Capability | Overload(110%~150%)for 30 seconds,then automatically transfer to bypass.when load is normal,it can automatically transfer to normal mode. | ||||||||||
Crest Factor | 3:1 | ||||||||||
Transfer Time | 0MS(AC to DC) | ||||||||||
Battery | |||||||||||
DC Supply Voltage | 36VDC | 96VDC | 96VDC | 240VDC | 240VDC | ||||||
Charge Current | 4A/8A(optional) | 4A/8A(optional) | 4A/8A(optional) | 4.2A | 4.2A | ||||||
Internal Battery Caoacity | (38/65/80/100AH)optional | ||||||||||
Panel Displsy | |||||||||||
LED | Load level/Battery level,Battry indicator,Unility Power,Bypass,Overload,Fault | ||||||||||
Communications | |||||||||||
Communicate Interface | RS232,SNMP Card(optional) | ||||||||||
Work Environment | |||||||||||
Temperature | -40° C~50° C | ||||||||||
Humidity | 0~95%(Non-condensing) | ||||||||||
Storage Temperature | -25° C~55° C | ||||||||||
Elevation | <1500m | ||||||||||
Physical Characterisstics | |||||||||||
Weight(KG) | N.W | 85 | 125 | 125 | 150 | 155 | |||||
Dimensions(WxDxH)mm | 613x640x954 | 650x753x1227 | 650x753x1227 | 940x940x1770 | 940x940x1770 |