• 1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series
  • 1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series
  • 1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series
  • 1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series

1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series

Phase: Single Phase
Type: On-line
Protection: Sealed Maintenance Free
Application: Communication
Classification: Lighting/Power
Standby Time: Long-acting Machine
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Centralized Model
Brand
Emerson
Output Power Factor
0.7 or 0.8 Optional
Voltage Range(1-3K)
115~300VAC
Voltage Range(6-20K)
176~276VAC
Frequency
50/60Hz
Overload Capability(1-3K)
110%~150% for 30sec, >150% for 200ms
Overload Capability(6-20K)
105%~130% for 10min, >130% for 1min
Recharge Time
5hrs to 90% of Capacity
Transfer Time
0ms
Transport Package
Standard Exported Carton and Pallets
Specification
CE; RoHS; ISO9001
Trademark
SOROTEC
Origin
China
Production Capacity
5000PCS/Month

Product Description

1kVA~20kVA Hihg Frequency True on Line Ups UPS HP9116C series 

Key Features:
1)Large Blue Back Light LCD for Detailed Real-Time UPS Status Display

2)High frequency UPS and double conversion on-line technology

3)Fully digitized microprocessor control

4)Microprocessor control guarantees high reliability

5)Comprehensive Self-Protection Design

6)Audible Alarm Mute

7)Cold Start Funcition

8)Auto Self-Testing System whileTurning on UPS

9)Wide Input Voltage Range

10)Automatic start & inspect

12)Zero transfer time

13)Advanced battery management

14)Automatic battery charge in UPS off mode

15)Lightning and surge protection

16)Short circuit and overload protection

17)Fan speed auto control when loads varies

18)Optional extension battery pack

19)Maintenance Bypass Switch For 6-20K

20)N+X Parallel Redundancy and Capaacity Expansion For 6-20K


Applications:
Servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom

Tendy&Elegant LCD Design for real-time UPS systm information:

1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series
Back Panel Description:

1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series

1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series


Technical Specifications of High Frequency Online UPS HP9116C 6-10K (1pH in/1pH out):
Model HP9116C 6-10KVA
6KT 6KT-XL 10KT 10KT-XL
Rated Power 6KVA/4800W 10KVA/8000W
Rated Voltage 220/230/240VAC
Rated Frequency 50/60 Hz
Input
VoltageRange 176~279VAC (± 3VAC)
FrequencyRange 50HZ: (46~54HZ); 60HZ: (56HZ~64HZ)
Power Factor 0.98
Output
Voltage Regulation 220/230/240X(1± 2%)VAC
Frequency Regulation 50/60 Hz± 0.05Hz
Power factor 0.7/0.8 (Optional) Standard 0.7
Voltage distortion Linear load< 3%      Non-linear load< 6%
Overload
Capability
110%~150% for 30s change to bypass model, Recover after load normal
Current Crest Ratio 3; 1
Transfer time 0ms (AC mode→ Battery mode)
Battery
DC Voltage 240VDC
Recharge Time 7hrs to 90% of capacity after full load discharge
Recharge Current 2A 4.2A 2A 4.2A
Display
LCD Display input/output Voltage, Frequency, Battery voltage, Battery capacity, Loading rate.
Communication
Interface Smart RS232, SNMP card (optional), USB (optional)
Environment
Operation Temperature 0~40 º C
Humidity 0~95%non-condensing
Storage Temperature -25 º C~55 º C
Sea level elevation < 1500m
Noise Level(1m) < 55dB
Physical Characteristic
Wright(KG) N. W. 81 35.5 84 36
G. W. 89 39.5 91 42
Dimension(D x W x H)mm 570X260 X717


Packaging & Shipping

1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series

Company Profile


Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards. 
1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series
1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series

Certifications

1,QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC. 

2,Best Partner

We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world. 

1kVA~20kVA Hihg Frequency True on Line UPS UPS HP9116c Series

FAQ

1.How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.

2.How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load. 
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.

3.How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.

4.How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.