Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Phase: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | SPS3115C 1-10KW | ||||||||
1kW | 1.5kW | 2kW | 3kW | 4kW | 5kW | 6kW | 8kW | 10kW | |
Input wave form | Sine wave (utility or generator) | ||||||||
Normal voltage | 120VAC(option) 230VAC | ||||||||
Low voltage re trip | 90V±4% & 184V/154V±4% | ||||||||
Low voltage re engage | 100V±4% & 194V/164V±4% | ||||||||
High voltage re trip | 140V±4% & 253V±4% | ||||||||
High voltage re engage | 135V±4% & 243V±4% | ||||||||
Normal input frequency | 50Hz/ 60Hz (auto detection) | ||||||||
Frequency range | 47Hz~65Hz | ||||||||
Output Wave form | (Bypass mode)same as input | ||||||||
Over-Load Protection | Circuit breaker | ||||||||
Short circuit Protection | Circuit breaker | ||||||||
Efficiency on line transfer mode | undefined95% | ||||||||
Line transfer time | 10ms Typical | ||||||||
Bypass without battery connected | Yes | ||||||||
Inverter output | |||||||||
Output wave form | Pure sine wave | ||||||||
Output continuos power watts | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 |
Surge ratings | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 |
Power factor | 0.9-1.0 | ||||||||
Nominal Output Voltage rms | 120VAC(option) 230VAC | ||||||||
Output Voltage regulation | +/- 10%rms | ||||||||
Output frequency | 50Hz ± 0.3Hz or 60Hz ± 0.3Hz | ||||||||
Short circuit protection | Yes,fault after 1 secs | ||||||||
Inverter input | |||||||||
Nominal input voltage | 24V/48V | 48V | |||||||
Minimum start voltage | 20V/40V | 40V | |||||||
Low battery alarm | 21V/42V | 42V | |||||||
Low battery trip | 20V/40V | 40V | |||||||
High voltage alarm | 32V/64V | 64V | |||||||
Charger | |||||||||
Output voltage | Dependent on battery type | ||||||||
Charge current | 10-85A MAX | 70A | 85A | ||||||
Battery initial voltage for start up | 0-15.7v for 12v(*2 for 24v;*4 for 48v) | ||||||||
Over charge protection | 15.7v for 12v(*2 for 24v;*4 for 48v) | ||||||||
Solar Charger | |||||||||
MPPT Range@Operating Voltage | 30-115VDC/60-115VDC | ||||||||
Maximum PV Array Open Circuit Voltage | 145VDC | ||||||||
Maximum Charging Current | 60A | ||||||||
Maximum Effciency | >96% |
APPLICATION OF OUR PRODUCT |
COMPANY SHOW |
WHY CHOOSE US ? |
FAQ |