True Double-Conversion 10-30kVA on Line UPS

Product Details
Customization: Available
Phase: Three Phase
Type: On-line
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
155
Year of Establishment
2006-07-03
  • True Double-Conversion 10-30kVA on Line UPS
Find Similar Products

Basic Info.

Model NO.
HP9335C Plus10-30KVA
Protection
Overvoltage
Application
Industry
Classification
Lighting
Standby Time
Standard Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Centralized Model
Brand
Sorotec
Model
HP9335c Plus 10-30kVA
Capacity
20kVA/9W
Power Factor
>0.9
Nominal Voltage
380/450/415VAC
Transfer Time
0ms
Battery Type
12V/9ah
Product Name
High Frequency Online UPS
Input Phase
Three Phase
Operation Temprature
0-40ºC
Transport Package
Standard Exported Cartons
Trademark
SOROTEC
Origin
China
Production Capacity
5000PCS/Month

Product Description

True Double-conversion 10-30kva On line UPS

Key Features:
1.True double-conversion
2.DSP technology guarantees high performance
3.Output power factor 0.9
4.Wide input voltage range (110-300 VAC)
5.Active power factor correction in all phases
6.50Hz/60Hz frequency converter mode
7.ECO mode operation for energy saving
8.Accepts dual-mains inputs
9.Emergency power off function (EPO)
10.Generator compatible
11.SNMP+USB+RS-232 multiple communications
12.3-stage extendable charging design for optimized battery performance
13.Adjustable battery numbers
14.Maintenance bypass available
15.Optional N+X parallel redundancy
16.Optional isolation transformer offers full isolation and complete common mode noise rejection

Reduce the investment cost saving valuable space:
HP9335C Plus Series UPS represents the best solution that is both cost effective and environmental friendly,It
delivers an excellent integrated autonomy, reduced footprint and optimum input and output performances,
guaranteeing reliable and flexible power.
True Double-Conversion 10-30kVA on Line UPS


Technical Specifications of Online UPS HP9335C Plus 10-30KVA

MODEL                                                         HP9335C Plus 10-30KVA
10K 10K-XL 15K 15K-XL 20K 20K-XL 30K 30K-XL
CAPACITY 10KVA / 9KW 15KVA / 13.5KW 20KVA / 18KW 30KVA / 27KW
PHASE                                                               3 Phase with Neutral
INPUT
Voltage Range Low Line Loss 110 VAC(Ph-N) ± 3 % at 50% Load;176 VAC(Ph-N) ± 3 % at 100% Load
Low Line Comeback Low Line Loss Voltage + 10V
High Line Loss 300 VAC(Ph-N) ± 3 %
High Line Comeback High Line Loss Voltage - 10V
Phase Three phase with ground
Power Factor ≥ 0.99 at 100% Load
OUTPUT
Output voltage 208/220/230/240VAC(Ph-N)
AC Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 46Hz ~ 54 Hz @ 50Hz system;56Hz ~ 64 Hz @ 60Hz system
Frequency Range (Batt.Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Overload AC mode 100%~110%:10min;110%~130%:1min;>130%:1sec
Battery mode 100%~110%:30sec;110%~130%:10sec;>130%:1sec
Current Crest Ratio 3:1 max
Harmonic Distortion <= 2 % @ 100% Linear Load;<= 5 % @ 100% Non-linear Load
Transfer Time Line←→Battery 0 ms
Inverte←→Bypass 0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass)
Line←→ECO <10 ms
EFFICIENCY
AC mode > 89% > 89% > 89% > 90%
Battery Mode > 86% > 88% > 87% > 89%
BATTERY
Standard Model Type




 
12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah
Numbers 20(18-20 adjustable) 2 x 20(18-20 adjustable) 2 x 20(18-20 adjustable) 3 x 20(18-20 adjustable)
Recharge Time 9 hours recover to 90% capacity
Charging Current 1.0 A ± 10% (max.) 2.0 A ± 10% (max.) 2.0 A ± 10% (max.) 4.0 A ± 10% (max.)
Charging Voltage 273 VDC ± 1%
Long-run Model Type Depending on applications
Numbers 18-20
Charging Current 4.0 A ± 10% (max.) 4.0 A ± 10% (max.) 4.0 A ± 10% (max.) 12.0 A ± 10% (max.)
Charging Voltage 273 VDC ± 1%
PHYSICAL
Standard Model Dimension, DxWxH(mm) 832 X250X894 832 X250X1275
Long-run Model Dimension, DxWxH(mm) 609 X250X768 832 X250X828
ENVIRONMENT
Operation Temperature 0 ~ 40°C (the battery life will down when > 25°C)
Operation Humidity <95 % and non-condensing
Operation Altitude <1000m
Acoustic Noise Level Less than 58dB @ 1 Meter Less than 60dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC
USB Power management from SNMP manager and web browser

True Double-Conversion 10-30kVA on Line UPS

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.