Basic Info.

Model NO.
HW9110E 1-10KVA
Protection
Unbalanced Loads
Application
Communication
Classification
Lighting/Power
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Sorotec
Nominal Voltage
220/230/240VAC
Nominal Frequency
50/60Hz
Frequency Range
50Hz(46~54Hz), 60h(56Hz~64Hz)
Voltage Precision
220/230/240X (1± 2%)VAC
Frequency Precision
50/60Hz± 0.05Hz
Power Factor
0.7/0.8(Optional)
Crest Factor
3:1
Internal Battery Capacity
(38/65/80/100ah)Optional
Temperature
0~40° C
Storage Temperature
-25° C~55° C
Transport Package
Wooden Pallet
Specification
CE
Trademark
SOROTEC
Origin
China
Production Capacity
500PCS/Month

Product Description

Outdoor UPS (HW9110E Series 1-10kVA) used for industry
Model: HW9110E 1-10kVA
Nominal voltage: 220/230/240VAC
Nominal Frequency: 50/60Hz
Output Power Factor"0.7/0.8(Optional)
KEY FEATURES:
1. SORO outdoor Intelligent High Frequency Online UPSS provide continuous pure sine wave AC power supply for outside communications/network equipment.

2. Double-conversion online design, high temperature resistant, anti-cold, sealing level for IP55; With the wide range of input voltage and frequency of input window(-45%+35% rated voltage and +-10% rated frequency). In many remote areas of China after a severe test of the grid).
APPLICATIONS:
This UPS is commonly used in the corner of the city, remote roads, mountains, bad environment, such as high temperature(+50° C)/ low temperature(-40V), severe dust, moisture, rain, mist erosion, every poor power quality(voltage durative higher than 260V or less than 160V, Frequency abnormal change) in the area.
Technical Specification:
Model HW9110E 1-10KVA
1KVA        2KVA        3KVA 6KVA 10KVA
Capacity 1KVA/0.7KW 2KVA/1.4KW 3KVA/.1KW 6KVA/4.2KW 10KVA/7KW
Nominal Voltage 220/230/240VAC
Nominal Frequency 50HZ/60HZ
Input  
Voltage Range 115~295VAC(±3VAC) 176~297VAC(±3VAC)
Frequency Range 50HZ:(46HZ~54HZ); 60HZ:(56HZ~6HZ)
Soft Start 0~100% 5sec
Power Factor 0.98
Output  
Voltage Precision 223/230/240x(1±2%)
Frequency Precision 50/60HZ±0.05HZ
Power Factor 0.7/0.8(Optional) Standard 0.7
Wave Distortion Linear load<3% Non-linear<6%
Overload Capability Overload(110%~150%)for 30 seconds,then automatically transfer to bypass.when load is normal,it can automatically transfer to normal mode.
Crest Factor 3:1
Transfer Time  0MS(AC to DC)
Battery  
DC Supply Voltage 36VDC 96VDC 96VDC 240VDC 240VDC
Charge Current   4A/8A(optional)   4A/8A(optional)   4A/8A(optional)      4.2A               4.2A
Internal Battery Caoacity (38/65/80/100AH)optional
Panel Displsy  
LED Load level/Battery level,Battry indicator,Unility Power,Bypass,Overload,Fault
Communications  
Communicate Interface RS232,SNMP Card(optional)
Work Environment  
Temperature -40° C~50° C
Humidity 0~95%(Non-condensing)
Storage Temperature -25° C~55° C
Elevation <1500m
Physical Characterisstics  
Weight(KG) N.W 85 125 125 150 155
Dimensions(WxDxH)mm 613x640x954 650x753x1227 650x753x1227 940x940x1770 940x940x1770


Packaging & Shipping

Outdoor UPS (HW9110E Series 1-10kVA) Used for Industry

Company Profile


Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards. 
Outdoor UPS (HW9110E Series 1-10kVA) Used for Industry
Outdoor UPS (HW9110E Series 1-10kVA) Used for IndustryOutdoor UPS (HW9110E Series 1-10kVA) Used for Industry

Certifications

1,QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC. 

2,Best Partner

We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world. 

Outdoor UPS (HW9110E Series 1-10kVA) Used for Industry

FAQ

1.How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.

2.How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load. 
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.

3.How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.

4.How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)