MODEL | IG3115CL 1-6KW Pure Sine wave Output Inverter | ||||||
1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Input Wave form | Sine wave (utility or generator) | ||||||
Nominal Voltage | 230Vac (120Vac optional) | ||||||
Low voltage trip | 90v ±4% & 184v/154v ±4% | ||||||
Low voltage re engage | 100v ±4% & 194v/164v±4% | ||||||
High voltage trip | 140v ±4% & 253v ±4% | ||||||
High voltage re engage | 135v ±4% & 243v±4% | ||||||
Nominal Input Frequency | 50Hz/ 60Hz (auto detection) | ||||||
Frequency range | 47Hz~65Hz | ||||||
Output Wave form | (Bypass mode)same as input | ||||||
Efficiency on line transfer mode | ≥95%+ | ||||||
Line transfer time | 10ms Typical | ||||||
Bypass without battery connected | Yes | ||||||
Inverter specification/output | |||||||
Output wave form | Pure sine wave | ||||||
Output continuos power watts | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 |
Output continuos power VA | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 |
Power factor | 0.9-1.0 | ||||||
Nominal Output Voltage rms | 230Vac (120Vac optional) | ||||||
Output Voltage regulation | +/- 10%rms | ||||||
Output frequency | 50Hz ± 0.3Hz or 60Hz ± 0.3Hz | ||||||
Safety Certification | >88% | ||||||
Surge ratings | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 |
Short circuit protection | Yes,fault after 1 secs | ||||||
Inverter specification/input | |||||||
Nominal input voltage | 12V/24V/48V | ||||||
Minimum start voltage | 10V/20V/40V | ||||||
Low battery alarm | 10.5V/21V/42V | ||||||
Low battery trip | 10V/20V/40V | ||||||
High voltage alarm | 16V/32V/64V | ||||||
Power saver | Same switched on/off on remote | ||||||
Charger mode specification | |||||||
Output voltage | Dependent on battery type | ||||||
Charge current | 0-85A MAX | ||||||
Battery initial voltage for start up | 0-15.7v for 12v(*2 for 24v;*4 for 48v;*8 for 96v) | ||||||
Over charge protection shutdown | 15.7v for 12v(*2 for 24v;*4 for 48v;*8 for 96v) | ||||||
Charger curves(4stage constant curren) | battery types | ||||||
4 step digital controlled progressive charge | |||||||
Battery type | Fast V Fast V(*2 for 24v;*4 for 48v) | ||||||
Gel U.S.A | 14 13.7 | ||||||
A.G.M. 1 | 14.1 13.4 | ||||||
A.G.M. 2 | 14.6 13.7 | ||||||
Sealed lead acid | 14.4 13.6 | ||||||
Gel euro | 14.4 13.8 | ||||||
Open lead acid | 14.8 13.3 | ||||||
Calcium | 15.1 13.6 | ||||||
De-sulphation | 15.5 for 4 hrs | ||||||
Remote control/RS232/USB | Yes. Optional |