Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1) Rated at 0.9 output power factor, more applicable to server computer and network
center that use PFC technology in a large scale, and deliver more Active power than
conventional UPS
2) Advanced distributed active parallel technology can realize parallel operation of 6 UPS
units without the need of centralized bypass cabinet
3) 6-inch extra large LCD that display 12 language( Chinese .English.Russian.Spanish.French…)
4) The efficiency of the machine is more than 94%, and reach 98% in ECO mode.
5) Intelligent battery management maintains battery automatically to prolong the battery life
6) Standard input/output filter improves the system EMC performance
Model | GP9335C | |||||||||||
Rectifier Type | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | ||
Rated Nominal | 120KVA/108KW | 160KVA/144KVA | 200KVA/180KW | 300KVA/270KW | 400KVA/36W | |||||||
Rated input voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||
Rated frequency | 50/60HZ | |||||||||||
Input parameters | ||||||||||||
Input voltage range | ±25% | |||||||||||
Input frequency range | 45Hz~65Hz | |||||||||||
Input soft start function | 0-100% 5-300settable | |||||||||||
Input power factor | >0.98(If harmonic filter is added) | |||||||||||
Input harmonic current (THDi) | <4.5%(If harmonic filter is added) | |||||||||||
Bypass | ||||||||||||
Bypass voltage range | -20%~+15% | |||||||||||
Bypass frequency range | 50/60HZ±10% | |||||||||||
Output parameters | ||||||||||||
Inverter output voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||
Voltage stability | ±1%(Steady status),±3%(Transient status) | |||||||||||
Frequency | 50/60Hz | |||||||||||
Mains power synchronization window | ±5% | |||||||||||
Actually measured frequency accuracy (internal clock) | 50/60Hz±0.01Hz | |||||||||||
Output power factor | 0.9(Output 90kW per 100kVA) | |||||||||||
Transient response time | <5ms | |||||||||||
Inverter overload capability | At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s | |||||||||||
Short circuit current from inverter |
3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds | |||||||||||
Maximum Bypasscapability | 1000% for 100ms | |||||||||||
Phase shift characteristic |
With 100% balanced load | <1° | ||||||||||
With 100% imbalance load | <1° | |||||||||||
Total harmonic Distortion(THDv) |
100% linear load | <1% | ||||||||||
100% non-linear load | <3% | |||||||||||
System efficiency (full load) | Up to 94% (inverter efficiency is up to 98%) | |||||||||||
Rectifier output parameters | ||||||||||||
Charger output voltage stability | 1% | |||||||||||
DC ripple voltage | ≤1% | |||||||||||
Operating environment | ||||||||||||
Operating temperature range | 0~40 ºC | |||||||||||
Storage temperature | -25~70ºC(Without battery) | |||||||||||
Relative humidity | 0~95%No condensation | |||||||||||
Maximum operating height | ≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100m | |||||||||||
Noise (1m) | 58-68dB | |||||||||||
Protection level | IP20 | |||||||||||
Standard | Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3 | |||||||||||
Physical parameters | ||||||||||||
Weight (kg) | 980 | 1420 | 1200 | 1750 | 1350 | 2000 | 1600 | 2200 | 2100 | 2750 | ||
Width(mm) | 900 | 1250 | 1250 | 1640 | 1250 | 1640 | 1640 | 2280 | 2280 | 2280 | ||
Depth (mm) | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | ||
Height (mm) | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 |