Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station

Product Details
Customization: Available
Condition: New
Certification: ISO, CE
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
155
Year of Establishment
2006-07-03
  • Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station
  • Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station
  • Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station
Find Similar Products
  • Overview
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SHW48500
Application
Industrial
Specification
Normal, CE
Type
AC to DC Power Supply for Solar Telecom Tower
Protection
Overload/Overcharge
Display
LCD&LED
Solar Charge Controller
50A /3000W MPPT
Cabinet
Aluminum
Suitable
Telecom Tower,Base Station,Traffic Lights
Input Voltage
220VAC
Output Voltage
48VDC
Phase
Single Phase
Service
OEM/Dem Produce
Transport Package
Export Carton
Trademark
SOROTEC
Origin
China Mainland
Production Capacity
6000PCS/Month

Product Description

48V 50A MPPT Solar Controller ac to dc Power Supply for Telecom Tower

Quick Detailes:
SHW48500 Series Solar DC Power System
220VAC Input 48VDC Output Solar Power Systems
Solar DC Power Solution for Telecom Equipments
Hot-swappable MPPT cntroller and Rectifier Modular Structure

Key Features:
1.Adopt advanced MCU microprocessor control technology
2.Advanced MPPT Technology.High converting efficiency higher than 97% for
  minimizing energy loss.
3.Reversed current protection at night.over voltage and reverse polarity protection
4.Capable of selection different charging mode fo various types of batteries
5.Protection degree:IP55
6.Industy-leading power density compact size and high reliability
7.Doorframe designed with waterproof structure, posted on the seal and equipped  with wateerproof lock in the door double insulation design
8.Cabine adopt quality galvanized wheet or aluminum coated steel sheet as material,   surfce coating anti-UV power
9.Suitable for outdoor installation
10.With remote monitoring system operation

Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station

SHW48500 Solar Power System =SHW48500 Solar Power System Cabinet+50A Solar Controller Module+50A 48VDC Rectifier+Monocrystal Solar Panel,grade A+Solar Panel Braket+Combiner Box

Typical Application:
Power plant or substation power for controlling, protection and automatic device, emergency lighting, communications ,steam turbine DC oil pump and so on independent DC systems. It can provide reliable power supply in the case of a power failure completely in plant or substation.The traditional DC systems connect battery pack and run with float charging mode.The new DC system run with silicon controlled rectifying power supply for battery.
Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station


Fine dust-proof, water-proof features
:

According to the overall standard of design dust-proof and water-proof IP55
1.With sun protection, heat insulation, roof ventilation
2.With waterproof and the filtration dust inlet, the cabinet front door shutters

Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station


 


Remote Monitoring System Interface:Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station

Technical Specifications of SHW48200 Solar DC Power System:

SHW48500 Solar System Rectifier Module(1-10)     MPPT Solar Charge Controller(1-10) 
INPUT
MPPT Range @Operating Voltage  60 ~150VDC
Maximum PV Array Power 3000W
Maximum Input Current 62A
OUTPUT
Nominal Battery Voltage  42-58VDC
Maximum Charge Current  50A(max:61A)
Maximum Efficiency 98%
Charging Method Three stages: bulk, absorption and floating
PROTECTION
Overload Protection  > 110% : audible alarm 
Overcharge Protection Yes
Polarity Reversal Protection @Solar Cell & Battery Yes
INDICATORS
LCD Panel  LCD panel indicating solar power, load level, battery voltage/capacity, charging current, and fault  conditions
LED Display Three indicators for solar, charging, and load status
Rectifier Module
Rated input voltage 220V
AC input Voltage range AC  90-290V
input Frequency range  45-65HZ
Power factor ≥0.99
Efficiency >92% 
Rated output voltage 48V
Rated output current  0-50A
Voltage range 42-58V
WIND CONTROLLER:  
Input Power 1KW/2KW
Input Voltage 150-300VAC
Output Voltage 48VDC
Ouput Current 30A/50A
ENVIRONMENT
Humidity 0 ~ 100% RH (No condensing)
Operating Temperature  -20°C to 55°C
Storage Temperature -40°C to 75°C
Altitude 0 ~ 3000 m


Packaging & Shipping

Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station

Company Profile


Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards. 
Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station
Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base StationRemote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station

Certifications

1,QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC. 

2,Best Partner

We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world. 

Remote Monitoring Solar Powered System with Hot Pluggable 50-500A for Bts Telecom Base Station

FAQ

1.How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.

2.How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load. 
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.

3.How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.

4.How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier