Outdoor UPS / Sinewave /Online UPS For Telecom and Network
Key Features:
1.SORO Outdoor Intelligent High Frequency Online UPS provide continuous pure sine wave AC power supply for outside communications / network equipment.
2.Double-conversion online design, high temperature resistant, anti-cold, sealing level for IP55; With the wide range of input voltage and frequency of input window (- 45% +35% rated voltage and ± 10% rated frequency), in many remote areas of China after a severe test of the grid.
Application:
This UPS is commonly used in the corner of the city, remote roads, mountains, bad environment, such as high temperature (+50 °C) / low temperature (-40 °C), severe dust, moisture, rain, mist erosion, very poor power quality (voltage longterm higher than 260V or less than 160V, frequency abnormal change) in the area.
High Reliability of the UPS System:
1.Using microprocessor control, directly produce highfrequency pulse width modulation wave (SPWM) control of the UPS inverter, to simplify the UPS control circuit, to improve the stability, to have more real-time UPS to quickly respond to changes in the external environment and guarantee the machine's control circuit is more simple and reliable.
2.Using digital control techniques, to avoid the traditional analog control temperature drift inherent defects such as hardware parameters, to ensure consistency and reliability
of UPS.
Technical Specifications:
Model |
HW9110E 1-10KVA |
1KVA |
2KVA |
3KVA |
6KVA |
10KVA |
Capacity |
1KVA/0.7KW |
2KVA/1.4KW |
3KVA/.1KW |
6KVA/4.2KW |
10KVA/7KW |
Nominal Voltage |
220/230/240VAC |
Nominal Frequency |
50HZ/60HZ |
Input |
|
Voltage Range |
115~295VAC(±3VAC) |
176~297VAC(±3VAC) |
Frequency Range |
50HZ:(46HZ~54HZ); 60HZ:(56HZ~6HZ) |
Soft Start |
0~100% 5sec |
Power Factor |
0.98 |
Output |
|
Voltage Precision |
223/230/240x(1±2%) |
Frequency Precision |
50/60HZ±0.05HZ |
Power Factor |
0.7/0.8(Optional) Standard 0.7 |
Wave Distortion |
Linear load<3% Non-linear<6% |
Overload Capability |
Overload(110%~150%)for 30 seconds,then automatically transfer to bypass.when load is normal,it can automatically transfer to normal mode. |
Crest Factor |
3:1 |
Transfer Time |
0MS(AC to DC) |
Battery |
|
DC Supply Voltage |
36VDC |
96VDC |
96VDC |
240VDC |
240VDC |
Charge Current |
4A/8A(optional) |
4A/8A(optional) |
4A/8A(optional) |
4.2A |
4.2A |
Internal Battery Caoacity |
(38/65/80/100AH)optional |
Panel Displsy |
|
LED |
Load level/Battery level,Battry indicator,Unility Power,Bypass,Overload,Fault |
Communications |
|
Communicate Interface |
RS232,SNMP Card(optional) |
Work Environment |
|
Temperature |
-40° C~50° C |
Humidity |
0~95%(Non-condensing) |
Storage Temperature |
-25° C~55° C |
Elevation |
<1500m |
Physical Characterisstics |
|
Weight(KG) |
N.W |
85 |
125 |
125 |
150 |
155 |
Dimensions(WxDxH)mm |
613x640x954 |
650x753x1227 |
650x753x1227 |
940x940x1770 |
940x940x1770 |
FAQ:
1.Output wave when take the full load
This product provide pure sine wave output when take the resistance load
...................................................................................................................................................
2.About THDI
Because this series product is not rectifier function, so can't make the THDI when use it
...................................................................................................................................................
3. About service
We are keep the most closely relationship with customers ,In order to satisfy the customer enjoy the most
perfect after- sales service.
...................................................................................................................................................
4.About SORO technology
We have the R&D department that is the core of the SORO. Shoulder heavy responsibilities of research , developing new product, perfecting the product . we are provide invests 10% of its annual revenue in research and development ,aims to offer customers in order to suited to their ever-changing environment enabling them to benefit from the last technological developments.
...................................................................................................................................................