Basic Info.

Model NO.
GP9335C 120-800KVA
Protection
Unbalanced Loads
Application
Communication
Classification
Lighting
Standby Time
Standard Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Sorotec
Operating Temperature Range
0~40 Oc
Transient Response Time
<5ms
Bypass Frequency Range
50/60Hz±10%
Bypass Voltage Range
-20%~+15%
Input Harmonic Current (Thdi)
<4.5%(If Harmonic Filter Is Added)
Input Power Factor
>0.98(If Harmonic Filter Is Added)
Input Soft Start Function
0-100% 5-300settable
Input Frequency Range
45Hz~65Hz
Input Voltage Range
±25%
Rated Frequency
50/60Hz
Transport Package
Wooden Case Pack for Export
Specification
CE, ISO9000
Trademark
SOROTEC
Origin
China
Production Capacity
6000PCS/Month

Product Description

Low Frequency Online UPS GP9335C 10-120KVA 3Ph in/3Ph out

Key Features:
1.  Use advanced 6th generation DSP and full digital
control technologies to realize higher system stability. 
2.  Output power factor is 0.9, carrying capacity than
conventional UPS with 10% above, as users reduce
investment cost. 
3.   Advanced distributed active parallel technology can
realize parallel operation of 6PCS UPS units without the need of centralized bypass cabinet.
4.   6-inch extra large LCD that can display 12 language (Chinese ,English,Russian,Spanish,French and so on).
5.   Extra wide input voltage and frequency range make it adapt to severe power grid environment.
6.   Intelligent battery management maintains battery automatically to prolong the battery life.
7.    Standard input/output filter improves the system EMC performance.
8.    Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety under extreme conditions.
9.    Layered independently-sealed ventilation channel and re-dundant fan, circuit boards with protective paints and a dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severe
environment.

Low Frequency Online UPS Gp9335c 10-120kVA 3pH in/3pH out
 
Applications:
Mainly used in large IDC rooms, bank/securities settlement center, communication network management center, semiconductor product lines and large automation production and its control system. According to the special needs of users was improved, and used in large sports venues, conference room, theater and highway and railway tunnels metal halide lamp lighting system.

Technical Specifications of three Phase UPS GP9335C 120-800kVA
Model GP9335C   120-800KVA
Rectifier Type 6p 12p 6p 12p 6p 12p 6p 12p 6p 12p
Rated Nominal 120KVA/108KW 160KVA/144KVA 200KVA/180KW 300KVA/270KW 400KVA/360KW
Rated input voltage 380/400/415VAC 3-phase 4-wire
Rated frequency 50/60HZ
Input parameters
Input voltage range ±25%
Input frequency range 45Hz~65Hz
Input soft start function 0-100%   5-300settable
Input power factor >0.98(If harmonic filter is added)
Input harmonic current (THDi) <4.5%(If harmonic filter is added)
Bypass
Bypass voltage range -20%~+15%
Bypass frequency range 50/60HZ±10%
Output parameters
Inverter output voltage 380/400/415VAC 3-phase 4-wire
Voltage stability ±1%(Steady status),±3%(Transient status)
Frequency 50/60Hz
Mains power synchronization window ±5%
Actually measured frequency accuracy (internal clock) 50/60Hz±0.01Hz
Output power factor 0.9(Output 90kW per 100kVA)
Transient response time <5ms
Inverter overload capability At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s
 
Short circuit current from inverter
3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds
Maximum Bypasscapability 1000% for 100ms
 
Phase shift
characteristic
With 100% balanced load <1°
With 100% imbalance load <1°
 
Total harmonic
Distortion(THDv)
100% linear load <1%
100% non-linear load <3%
System efficiency (full load) Up to 94% (inverter efficiency is up to 98%)
Rectifier output parameters
Charger output voltage stability 1%
DC ripple voltage ≤1%
Operating environment
Operating temperature range 0~40 ºC
Storage temperature -25~70ºC(Without battery)
Relative humidity 0~95%No condensation
Maximum operating height ≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100m
Noise (1m) 58-68dB
Protection level IP20
Standard Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3
Physical parameters
Weight (kg) 980 1420 1200 1750 1350 2000 1600 2200 2100 2750
Dimension(WxDxH)mm 900x855x1900 1250x855x19001900 1640x855x1900 1250x855x1900 1640x855x19001900 2280x855x190019001900