ISO Certified DC to AC Power Inverter with High Speed Rack Tower Design
Key Features:
1.Pure sine wave output
2.The charging current is big up to 85 Amp
3.Output power factor:s 0.9-1
4.Well accept generator's output
5.Full automatical and silent operation
6.Automatically transfer between battery and line modes
7.Microprocessor control guarantees high reliability
8.Remote control function
9.Three-steps intelligent charging control to recharging time
10.Bypass and bypass voltage regulation function
11.Could be setting frequency by LCD display with color screen
12.Battery type and charge current can be select
Full protection:
Protection for low battery voltage ,over load ,output short circuit and over- temperature restrain surge interference,eliminate noise,protection for thunder striking,provide the reliable power to the home appliances.
Applications:
Supply the reliable long back up time power for the home appliances and office appliances Solar power systems etc.
Technical Parameters:
MODEL |
IG3115CS 1-12KW Pure Sine wave Output Inverter |
1KW |
1.5KW |
2KW |
3KW |
4KW |
5KW |
6KW |
8KW |
10KW |
12KW |
Input Wave form |
Sine wave (utility or generator) |
Nominal Voltage |
230Vac (120Vac optional) |
Low voltage trip |
90v ±4% & 184v/154v ±4% |
Low voltage re engage |
100v ±4% & 194v/164v±4% |
High voltage trip |
140v ±4% & 253v ±4% |
High voltage re engage |
135v ±4% & 243v±4% |
Nominal Input Frequency |
50Hz/ 60Hz (auto detection) |
Frequency range |
47Hz~65Hz |
Output Wave form |
(Bypass mode)same as input |
Efficiency on line transfer mode |
≥95%+ |
Line transfer time |
10ms Typical |
Bypass without battery connected |
Yes |
Inverter specification/output |
Output wave form |
Pure sine wave |
Output continuos power watts |
1000 |
1500 |
2000 |
3000 |
4000 |
5000 |
6000 |
8000 |
10000 |
12000 |
Output continuos power VA |
1000 |
1500 |
2000 |
3000 |
4000 |
5000 |
6000 |
8000 |
10000 |
12000 |
Power factor |
0.9-1.0 |
Nominal Output Voltage rms |
230Vac (120Vac optional) |
Output Voltage regulation |
+/- 10%rms |
Output frequency |
50Hz ± 0.3Hz or 60Hz ± 0.3Hz |
Safety Certification |
>88% |
Surge ratings |
3000 |
4500 |
6000 |
9000 |
12000 |
15000 |
18000 |
24000 |
30000 |
36000 |
Short circuit protection |
Yes,fault after 1 secs |
Inverter specification/input |
Nominal input voltage |
12V/24V/48V |
48V/96V |
Minimum start voltage |
10V/20V/40V |
80V |
Low battery alarm |
10.5V/21V/42V |
84V |
Low battery trip |
10V/20V/40V |
80V |
High voltage alarm |
16V/32V/64V |
128V |
Power saver |
Same switched on/off on remote |
Charger mode specification |
Output voltage |
Dependent on battery type |
Charge current |
0-85A MAX |
70/35A |
85/45A |
100/50A |
Battery initial voltage for start up |
0-15.7v for 12v(*2 for 24v;*4 for 48v;*8 for 96v) |
Over charge protection shutdown |
15.7v for 12v(*2 for 24v;*4 for 48v;*8 for 96v) |
Charger curves(4stage constant curren) |
battery types |
4 step digital controlled progressive charge |
Battery type |
Fast V Fast V(*2 for 24v;*4 for 48v) |
Gel U.S.A |
14 13.7 |
A.G.M. 1 |
14.1 13.4 |
A.G.M. 2 |
14.6 13.7 |
Sealed lead acid |
14.4 13.6 |
Gel euro |
14.4 13.8 |
Open lead acid |
14.8 13.3 |
Calcium |
15.1 13.6 |
De-sulphation |
15.5 for 4 hrs |
Remote control/RS232/USB |
Yes. Optional |
APPLICATION OF OUR PRODUCT |
1. Living house and home building
2. Office building, factory and warehouse
3. Shopping mall, stadium and so on
4. Power station, field operation and some huge engineer construction
5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip
Introduction of Company
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.
1, QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2, Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.
1. How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power
.......................................................................................................................................................................
2. How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the
size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load.
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.
.......................................................................................................................................................................
3. How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions
.......................................................................................................................................................................
4. How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
.......................................................................................................................................................................